Total
Cold Chain Monitoring
Solution
  Smart Label with Temperature Logger
  LOW COST, Small, Rugged, Self-sufficient Cold-Chain Monitoring Packing Label system.
Time and temperature monitoring labels are flat, about the size of a sugar packet (45mm x 57mm), and are able to digitally
record time and temperature of a product’s environment during the entire distribution cycle.
First, LEDs indicate if a shipment remained within acceptable temperature specifications. A flashing green LED indicates
conditions were always within acceptable parameters; yellow indicates conditions drifted outside of acceptable range and data
should be downloaded from the label for further examination.
Temperature range: Can be customise, Acc.: ± 0.5oC)
Logger Memory: 4kb readings (80 days of readings taken at 30 minute intervals)
Logging interval: Preprogrammed for 5 minute to 50 minutes.
Shelf Life: 6 months from date of purchase
 
COLDMARK
A Freeze Indicator To Monitor Damaging Cold Temperatures
Some temperature-sensitive products must never be exposed to temperatures below freezing.  The ColdMark Freeze Indicator
is a self-activating tool that tells you if your product has been exposed to freezing conditions. This means it puts you in control
even after your product has been shipped. At a glance your customer will know whether there has been exposure to abusive
temperatures.
How ColdMark works.
When the temperature dips below a freezing point, the clear, colourless indicator bulb changes to a violet colour. It's a
clear-cut indicator of freezing - and this colour change can not be reversed. Because various products are affected at different
temperatures, ColdMark Freeze Indicators are available in several different threshold temperatures.
Easy to use.
From room-temperature storage to application, ColdMark Freeze Indicators are designed for simplicity - an easily added step
to shipping operations.  When you're ready to use ColdMark, simply peel off the back liner and place ColdMark in the
environment you wish to monitor.  That's all there is to it!
ColdMark ensures consistent product quality.
Whether you're shipping medical products, pharmaceuticals, paint, or other cold-sensitive products, ColdMark Freeze
Indicators are a convenient, accurate tool for monitoring cold temperature extremes.  Use ColdMark to ensure a higher degree
of customer satisfaction.
 
WARMMARK
LOW COST Monitoring The Duration Of Exceeding Damaging Temperatures
Certain temperature-sensitive products must be kept cool. WarmMark Time-Temperature Indicators monitor your products
during storage and shipment, giving you an accurate, non-reversible record of temperature exposure with the passage of time.
WarmMark Indicators come in a variety of response temperatures to fit many applications.
How WarmMark works.
If the windows in the WarmMark Indicator stay white, there's no problem.  But if the temperature climbs beyond a certain
threshold, a red color gradually moves through the windows of the WarmMark Indicator with the passage of time.  If the
temperature returns to below the threshold, the color stops moving.  In this way, you can estimate how long your product was
exposed above the threshold temperature.
Stay in control.
Even after your products been shipped, WarmMark helps you keep the upper hand on temperature and product quality.  Give
your customers an added level of security and product confidence with WarmMark Indicators.
WarmMark Time-Temperature Indicators
tell you if your product has been exposed to warmer-than-acceptable temperatures overtime.  Three WarmMark models are
available in a variety of threshold temperatures.
  ExcelTemp Temperature Logger
LOW COST, Small, Rugged, Self-sufficient Cold-Chain Monitoring system
Globally unique ID address
Temperature range: -300C to +85oC (Res.: 0.5oC, Acc.: ± 1.0oC)
(Others range also available upon request)
Logger Memory: 2048 readings (6 weeks of readings taken at 30 minute intervals)
Logging interval: Adjustable from 1 minute to 4 hours 15 minutes.
Battery Lifetime: > 10 years or up to 1 million Temperature measurements
  MicroLog Datalogger:  EC600 (Temperature), EC650 (Temperature &
Humidity)
Temperature: -30º to 50º C (res. 0,5º C; accuracy. ±0.6º C)
Humidity: 0 to 100% (res. 0,5% ; accuracy ±3% @ 25º C)
1 external sensor: light; contact; pH; voltage; current and more…
2 buttons & 7 segments  2 digit LCD
View up to 30 days of min/max
Serial Port (RS-232) , IrDA for printer and PC
Sampling rate from every 10 sec to every two hours
Memory of 16,000 samples
Built in calendar and clock
Dimensions: diameter - 72 mm; thickness 23 mm
Weight: 55 g
IP 65 for EC600 model and IP60 for model EC650
  MicroLog Datalogger (10 bit):  EC700 (Temperature), EC750
(Temperature & Humidity)
Temperature: -40º to 80º C (res. 0.2º C; accuracy. ±0.2º C)
Humidity: 0 to 100% (res. 0.1% ; accuracy ±3% @ 25º C)
1 external sensor: light; contact; pH; voltage; current and more…
2 buttons & 7 segments  3 digit LCD
View up to 30 days of min/max
Serial Port (RS-232) , IrDA for printer and PC
Sampling rate from every 10 sec to every two hours
Memory of 52,000 samples
Built in calendar and clock
Dimensions: diameter - 72 mm; thickness 23 mm
Weight: 55 g
IP 65 for EC700 model and IP60 for model EC750
  MicroLog External Sensors
  • Temperature (-50º to 100º C)   2.5m length and 8m length,   Needle probe option  -cable length 2.5m
  • Light (0 a 5000 Lux)
  • pH (0 - 14)
  • Contact
  • Current (4 - 20 mA)
  • Voltage (0 a 10 V)
  • PT100 (-10 to 10) or (-100 to 120)
  • Conductivity (0 to 20 mS)
  MicroLog Alarm Cradle
Alarm device
Communication: Serial and USB
Power: Battery or external
Connectors for external sensors and external antenna
OC to activate external device when alarm is crossed
Terminal board for: External power , external sensor, contact sensor , OC low and OC high alarm
  MicroLog Wireless Cradle
Receiver

Transmitter and alarm device
Range: 300m – outdoor; 75m - indoor
Communication: Serial and USB
Power: Battery or external
Transmission: On-line, programmed daily downloads, and initiated downloads
Connectors for external sensors and external antenna
OC to activate external device when alarm is crossed
Terminal board for: External power , external sensor, contact sensor , OC low
and OC high alarm
Repeater
 
Temperature & Humidity Logger
The DL-1 and DL-2 are a new, low cost, temperature and relative humidity data loggers for use wherever these parameters
need to be monitored.
Museums, hospitals, pharmacy, laboratories, schools, transport, agriculture, and many others.
The DL-1 a 14Bit device that measures Temperature, one internal and one optional external channel.
The DL-2 a 12 Bit device measures Relative Humidity & Temperature with self contained sensors.
Size is 65x65x28mm ABS plastic Temperature range -40 to + 85 degrees C, RH range 0 to 100%RH
 
SOXXX & ROXXX Series Temperature Logger
Available Model:
1 x IntTemp
(With/Without Display)
1 x ExtTemp
2 x ExtTemp
2 x Int&ExtTemp
4 x ExtTemp
2 x ExtTemp + 2 x Binary
  • Temperature Range: -30 to +80°C, -40 to +80°C logger R0110
  • Accuracy: Pt-1000 external probe ±0.2°C from -50 do +100°C; Internal Sensor: ±0.4°C
  • Resolution: 0.1°C
  • large data memory 32000 values
  • large dual line display with special symbols, switchable
  • optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
  • dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LED diode
  • two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is
    cleared from the PC)
  • robust case, easy installation, locking enabled
  • low power consumption from battery, up to 7 years lifetime, easy replacement of the battery
  • indication of remaining battery life
  • standard temperature sensor is Pt1000, switchable to Ni1000/6180ppm external probes at range -50 to +150°C
  • it is possible to combine temperature measurement with logging of contact state (e.g. door contact)
  • logging start/stop is enabled in several ways: at certain time and date programmed from computer, by delivered magnet
    or depending on binary input state
  • also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm
    limits
  • each logger is possible to describe with text of maximum 32 characters
  • each channel is possible to describe with text of maximum 16 characters
  • password protection is enabled to prevent unauthorized manipulation with logger
Wall Lock
 
S3XXX & R3XXX Series Temperature & Humidity Logger
Available Model:
1 x IntTemp/RH
(With/Without Display)
1 x ExtTemp/RH
(with/Without Display)
1 x IntTemp/RH + 1 x
ExtTemp
1 x IntTemp/RH + 2
x0..5V
  • Temperature Range: -30 to +80°C, -40 to +80°C logger R0110
  • Accuracy: Pt-1000 external probe ±0.2°C from -50 do +100°C; Internal Sensor: ±0.4°C
  • Accuracy of Humidity measurement: 2.5% RH from 5-95%RH at 23°C
  • Accuracy of dew point: 0.5°C from 30-95%RH
  • Resolution: 0.1°C / 0.1%RH
  • large data memory 32000 values
  • large dual line display with special symbols, switchable
  • optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
  • dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LED diode
  • two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is
    cleared from the PC)
  • robust case, easy installation, locking enabled
  • low power consumption from battery, up to 7 years lifetime, easy replacement of the battery
  • indication of remaining battery life
  • standard temperature sensor is Pt1000, switchable to Ni1000/6180ppm external probes at range -50 to +150°C
  • it is possible to combine temperature and RH measurement with measurement of two user calibrated voltage signals 0-
    5V from any transducer
  • logging start/stop is enabled in several ways: at certain time and date programmed from computer, by delivered magnet
    or depending on binary input state
  • also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm
    limits
  • each logger is possible to describe with text of maximum 32 characters
  • each channel is possible to describe with text of maximum 16 characters
  • password protection is enabled to prevent unauthorized manipulation with logger
 
 
   
 
 
   
 
 
 
 
 
 
   
web counter